PrimeWall® Stud

Each PrimeWall® Stud contains knurled flanges for fastener efficiency.

Members / PrimeWall®

PrimeWall® Stud

Section Properties - Allowable Heights (Composite) - Allowable Heights (Non-Composite)

The PrimeWall® Drywall Studs are used in non-load-bearing wall systems that support gypsum board construction. PrimeWall® Studs are available in 18mil, 27mil, and 30mil (25, 22 and 20 gauge-non-structural) thicknesses, and 1.625”, 2.5”, 3.5”, 3.625”, 4”, 5.5”, and 6” depths. Each PrimeWall® Stud is manufactured from mill-certified steel meeting the following requirements:
ASTM A1003/A 1003M Non Structural Grade 33 (230), 33 ksi (230 MPa) minimum yield strength, G40 (Z120) hot-dipped galvanized coating, or equivalent conforming to ASTM C645. Other steel materials with G40 coating are also available upon request.

Each PrimeWall® Stud contains knurled flanges for fast fastener placement when connecting sheathing. Pre-punched knockouts are spaced at regular intervals for rapid installation of bridging, electrical wiring, and plumbing.
Because The Steel Network is committed to improving overall quality in the construction industry, we insist on utilizing traceable material for all steel in the manufacturing of the PrimeWall® Series.

It is the goal of The Steel Network to improve the quality of steel framing construction.

Download PrimeWall® Stud Technical Information (PDF)

Minimum Thickness1 (mils) Design Thickness (in) Inside Corner Radii (in) Reference Gauge No.
18 0.0188 0.0843 25
27 0.0283 0.0796 22
30 0.0312 0.0781 20 - Drywall


Minimum Thickness represents 95% of the design thickness and is the minimum acceptable thickness delivered to the job site based on Section A3.4 of the AISI Specification.

Member

The Steel Network is a member of
the Steel Stud Manufacturers Association

 

PrimeWall® Stud Available Sections

162S125-xx 250S125-xx 350S125-xx 362S125-xx 400S125-xx 550S125-xx 600S125-xx 800S125-xx
.75" wide knockout in 1.625" and 2.5" studs 1.5" wide knockout in 3.5" and wider studs with knockouts spaced 24” o.c.

Knockouts begin 12” from the bottom and are spaced vertically every 24” o.c. for East & Central Region studs; for West Region studs, knockouts begin 24” from the bottom and are spaced vertically every 24” o.c.


 

          Products are available through local distribution.