VertiClip® SL Exterior Head Of Wall

Product Application

VertiClip® SL connects the exterior curtain wall studs at head of wall to the building frame while allowing for vertical deflection of the structure up to 1½” (¾” up and down). VertiClip’s unique design provides both an anti-friction and anti-seizure connection between the clip and the stud web surface thereby preventing a transfer of vertical forces into curtain wall framing, which is not engineered to support axial loads. Use of VertiClip SL over friction-fit track assemblies helps protect liability through the utilization of positive mechanical attachments to the web of the stud. VertiClip SL is a component of VertiTrack® VTX, our preassembled deflection track
Click Here to View. Allowable loads are based on use of two #12 screws for attachment to stud (provided by TSN).

An ICC-ES Evaluation Report for VertiClip SL362, 600, and 800 is available.
Click here to view the report
A Los Angeles Research Report for VertiClip SLD, SL, SLB, SLS, and SLT Series is available. Refer to LARR #25631. Click here to view the report.

 

VertiClip SL DimensionsMaterial Composition

ASTM A653/A653M, Grade 50 (340), 50ksi (340 MPa) minimum yield strength, 65ksi (450 MPa) minimum tensile strength, G-90 (Z275) hot-dipped galvanized coating. Material thickness = 68mil (14 gauge, 0.0713” design thickness).

The attachment of VertiClip to the primary structure may be made with PAF or weld and is dependent upon the base material (steel or concrete) and the design configuration.

Allowable load tables incorporate eccentric loading of fasteners. Values with welded connection may increase.

Note:

  • Fasten within ¾” from the angle heel (centerline of the 1½” leg) to minimize eccentric load transfer.
  • Guide holes for attachment to structure are .172” in diameter, and are standard for SL362, and SL600.
  • Deflection requirements greater than ¾” (up and down) are available.

VertiClip SL series is designed to support horizontal loads and should not be used in axial-load-bearing wall construction.

Back to top ^


VertiClip SL Installation

  1. Attach 20ga standard leg track to structure. Track will allow for alignment and closure.
  2. Fasten SL to top track at designed stud spacing with engineered fastener.
  3. Attach SL to wall stud with provided screws through Step Bushings.
Quality Features
  • Load-rated positive mechanical attachment at each stud
  • Eliminates friction-held assemblies
  • Utilizes only mill-certified, 50ksi steel
  • Step Bushings pre-installed for accurate placement
  • Load rated screws provided for each VertiClip
  • Meets all building code criteria
  • Adaptable for multiple configurations
Labor Benefits
  • Top of wall bridging or strapping is eliminated
  • Top track lightweight for easy handling (not a structural element, may be 20ga standard leg - Deep-Leg Track is not required)
  • Utilize clips for wall layout
  • Eliminates temporary screws

Back to top ^

VertiClip SL Nomenclature

To designate the proper clip on drawings, multiply stud depth by 100. VertiClip SL is sized to match stud depth.

Example: 6” stud.
Designate SL600.

Back to top ^

Quantity / Order Information
Designation
Qty/Box
Lbs/Box
Pcs/Skid
Lbs/Skid
SL362
100
37
4500
1665
SL400
100
38
4500
1710
SL600
100
55
4500
2475
SL800
50
41
2250
1845
SL1000
50
40
2250
1800
SL1200
50
57
2250
2565

Back to top ^

Allowable (Unfactored) Loads1
VertiClip Series
Load
Direction
Stud
Thickness
Mils (ga)
Fy (yield) Stud
(ksi)
SL362
F2 w/ 2 #12
screws
(kips)
SL400
F2 w/ 2 #12
screws
(kips)
SL400
F2 w/ 3 #12
screws
(kips)
SL600
F2 w/ 2 #12
screws
(kips)
SL600
F2 w/ 3 #12
screws
(kips)
SL
(Clip is14ga,
68mils)

F2

33 (20)
33
0.377
0.377
0.565
0.377
0.565
33 (20)
50
0.544
0.544
0.817
0.544
0.817
43 (18)
33
0.561
0.561
0.841
0.561
0.841
43 (18)
50
0.790
0.810
1.136
0.810
1.215
54 (16)
33
0.789
0.789
1.136
0.789
1.183
54 (16)
50
0.790
1.136
1.136
1.139
1.680
68 (14)
50
0.790
1.136
1.136
1.610
1.680
97 (12)
50
0.790
1.136
1.136
1.680
1.680
VertiClip Series
Load
Direction
Stud
Thickness
Mils (ga)
Fy (yield) Stud
(ksi)
SL362
F1 w/ 2 #12
screws
(kips)
SL400
F1w/ 2 #12
screws
(kips)
SL600
F1 w/ 2 #12
screws
(kips)
SL600
F1 w/ 3 #12
screws
(kips)
SL
(Clip is14ga,
68mils)

F1

33 (20)
33
0.190
0.190
0.190
0.285
33 (20)
50
0.248
0.199
0.275
0.367
43 (18)
33
0.248
0.199
0.248
0.367
43 (18)
50
0.248
0.199
0.359
0.367
54 (16)
33
0.248
0.199
0.312
0.367
54 (16)
50
0.248
0.199
0.367
0.367
68 (14)
50
0.248
0.199
0.367
0.367
97 (12)
50
0.248
0.199
0.367
0.367
VertiClip Series
Load
Direction
Stud
Thickness
Mils (ga)
Fy (yield) Stud
(ksi)
SL800
F2 w/ 2 #12
screws
(kips)
SL800 F2
w/ 3 #12
screws
(kips)
SL1000
F2 w/ 2 #12
screws
(kips)
SL1000
F2 w/ 3 #12
screws
(kips)
SL1200
F2 w/ 2 #12
screws
(kips)
SL1200
F2 w/ 3 #12
screws
(kips)
SL
(Clip is 14ga,
68mils)

F2

33 (20)
33
0.377
0.565
0.377
0.565
0.377
0.565
33 (20)
50
0.544
0.817
0.544
0.817
0.544
0.817
43 (18)
33
0.561
0.841
0.561
0.841
0.561
0.841
43 (18)
50
0.810
1.215
0.810
1.215
0.810
1.215
54 (16)
33
0.789
1.183
0.789
1.183
0.789
1.183
54 (16)
50
1.139
1.709
1.139
1.577
1.139
1.709
68 (14)
50
1.610
1.870
1.577
1.577
1.610
1.791
97 (12)
50
1.698
1.870
1.577
1.577
1.698
1.791
VertiClip Series
Load
Direction
Stud
Thickness
Mils (ga)
Fy (yield) Stud
(ksi)
SL800
F1 w/ 2 #12
screws
(kips)
SL800
F1 w/ 3 #12
screws
(kips)
SL1000
F1 w/ 2 #12
screws
(kips)
SL1000 F1
w/ 3 #12
screws
(kips)
SL1200
F1 w/ 2 #12
screws
(kips)
SL1200
F1 w/ 3 #12
screws
(kips)
SL
(Clip is 14ga,
68mils)

F1

33 (20)
33
0.190
0.285
0.190
0.285
0.190
0.285
33 (20)
50
0.275
0.362
0.275
0.413
0.275
0.381
43 (18)
33
0.248
0.362
0.248
0.372
0.248
0.372
43 (18)
50
0.359
0.362
0.359
0.414
0.359
0.381
54 (16)
33
0.312
0.362
0.312
0.414
0.312
0.381
54 (16)
50
0.362
0.362
0.414
0.414
0.381
0.381
68 (14)
50
0.362
0.362
0.414
0.414
0.381
0.381
97 (12)
50
0.362
0.362
0.414
0.414
0.381
0.381

Allowable loads have not been increased for wind, seismic, or other factors.

  • Two #12 screws are provided with each VertiClip SL.
  • If loads justify use of a third screw, TSN will provide 3 slots and 3 screws with each clip.

 1For LRFD Design Strengths refer to ICC-ESR-1903.

Back to top ^

Load Direction

VertiClip SL Load Direction
US Patents #5,467,566 & #5,906,080

Back to top ^

 

  Oct 2008   

 


          Products are available through local distribution.
Build #: 27