VertiTrack® VTD Head of Wall Slip Connector

Product Application

The VertiTrack® deflection track system is used to connect the interior studs at head of wall while allowing for a vertical deflection of the structure up to 1½” (¾” up and ¾” down). VertiClip’s® unique design provides both an anti-friction and anti-seizure
connection between the clip and the stud web surface, thereby preventing a transfer of vertical forces into drywall partition framing, which is not designed to support axial loads. VertiTrack VTD is composed of VertiClip SLD pre-attached to a top runner track at pre-designated stud spacing.

 

VertiTrack VTD DimensionsMaterial Composition

Track and clip material: ASTM A653/A653M, Grade 50 (340),
50ksi (340 MPa) minimum yield strength, 65ksi (450 MPa)
minimum tensile strength, (clip); 33ksi (230MPa) minimum yield
strength, 45ksi (310 MPa) minimum tensile strength (track);
G-60 (Z180) hot-dipped galvanized coating (clip & track). Track
leg length = 1½”. Track and clip material thickness = 33mil (20
gauge, 0.0346” design thickness).

The attachment of VertiClip to the primary structure may be
made with a PAF and is dependent upon the base material
(steel or concrete) and the design configuration.

Note:

  • Fasten within ¾” from the angle heel (centerline of the 1½” leg) to minimize eccentric load transfer.
  • Fasten through each VertiClip SLD to structure.

VertiTrack VTD is designed to support horizontal loads, and should not be used in axial-load-bearing walls. VertiTrack VTD is assembled with VertiClip SLD pre-attached at 16” o.c. and 24” o.c. Custom spacing is also available. Screws and step bushings are provided for attachment of VertiClip to the stud web.


Back to top ^

VertiTrack VTD Nomenclature

VertiTrack is manufactured in 12 ft. lengths. VertiTrack is designated by type (VTD), followed by stud depth in inches multiplied by 100 and stud spacing.

Example: 6” deep stud, 16” on center

Designate: VertiTrack VTD600-16.

VertiTrack VTD Value
  • Load-rated positive mechanical attachment at each stud
  • Eliminates friction-held assemblies
  • Clip utilizes only mill-certified, 50ksi steel
  • Step Bushings pre-installed for accurate placement
  • Load rated screws provided for each VertiClip
  • Meets all building code criteria
  • Adaptable for multiple configurations
  • Top of wall bridging or strapping is eliminated
  • Track lightweight for easy handling
  • Utilize clips for wall layout
  • NY MEA approval #326-06-M
  • Listed in ICBO report #ES-5614


Back to top ^

VertiTrack VTD Installation
  1. Attach VertiTrack VTD to deck with approved fasteners.
  2. Attach VertiClip through Step Bushings to wall studs with self-drilling screws provided.
  Quantity / Order Information 
Designation
Lbs / Piece
Qty/Skid
(Pieces)
Qty/Skid
(Feet)
Lbs / Skid
VTD250-16
8.808
250
3000
2200
VTD250-24
8.472
250
3000
2118
VTD362-16
10.935
242
2904
2647
VTD362-24
10.410
242
2904
2520
VTD400-16
11.415
200
2400
2283
VTD400-24
10.890
200
2400
2178
VTD600-16
15.240
98
1176
1494
VTD600-24
14.400
98
1176
1412
VTD800-16
18.810
100
1200
1881
VTD800-24
17.700
100
1200
1770

Back to top ^

  Allowable Loads  

VertiTrack VTD loads are the same as VertiClip SLD loads.

 

 Oct 2008   

 

 


          Products are available through local distribution.
Build #: 27