MidWall™ |
Partial Wall Framing and Base Connection |
|
|
Product Application
|
MidWall™ is designed to support out-of-plane loading in partial
wall systems that are unsupported at the top track. The out-of-plane loads are transferred
to the floor system through a ˝” thick plate nested in the flanges of the member
with two 3/8” diameter fasteners used for the connection. Available in two lengths,
24” and 48”. MidWall™ may be used in place of standard framing members, or in conjunction
with them to frame the wall.
Material
Composition
MidWall™: ASTM A1003/A 1003M, ASTM A653/A653M, Grade 50 (340),
50ksi (340MPa) minimum, 65ksi (450MPa) minimum yield strength, G-90 (Z275) hot-dipped
galvanized coating. Material Thickness = 118mil (10 gauge, 0.1017” design thickness)
MidWall™ Plate: ASTM A36/A36M 08, 36ksi (250MPa) minimum yield
strength, 58-80ksi (400-500MPa) tensile strength, ˝” thick.
|
|
|
MidWall™ Value:
- Replaces labor/coordination of placing embedded angle into the floor system
- Provides guide holes for attachment of MidWall™ to the stud (more
efficient attachments compared with tube steel)
- Reduces the number of anchors used (2 in MidWall™ vs. 4 in other
methods)
- Creates flexibility as two sizes of MidWall™ are available (24” and 48”) to enable
adjustable wall heights
- current code requirements for handrails and partial walls
|
|
Back to top ^
MidWall™
Nomenclature
MidWall™ is currently available in two lengths (24” and 48”) and
one depth (3.625”). Product nomenclature lists the member depth first followed by
the height in inches.

- For 24” MidWall™, designate 362MW-24
- For 48” MidWall™, designate 362MW-48
MidWall™
Ordering Information
MidWall™ is available by the box or in pallet (skid) quantities
through your local dealer. Each MidWall™ product will be shipped with a separate
base plate.
|
Designation
|
Pcs/Box
|
Lbs/Pc
|
Pcs/Skid
|
Lbs/Skid
|
|
362MW-24
|
8
|
7.5
|
160
|
1200
|
|
362MW-48
|
4
|
13.5
|
120
|
1500
|
Back to top ^
|
MidWall™
Installation
|
MidWall™
24” Assembly Example
|
MidWall™
48” Assembly Example
|
|
|
|
MidWall™ 24” is generally used in interior half walls of less than
48” in height. Attach MidWall 24" to stud with #12 screws through all pre-drilled
guide holes. Maximum spacing between MidWall™ connectors is 36”
o.c. (see table below). Contact TSN Technical Services at (888) 474-4876 for design
recommendations.”
|
MidWall™ 48" is used in interior half walls equal to 48" in height.
Use one MidWall 48" as a substitute for a stud at the specified spacing. Maximum
spacing between MidWall™ connectors is 36" o.c. (see table below).
Contact TSN for technical support regarding use in exterior or 6" wide walls.
|
Back to top ^
MidWall™
Design Information
Criteria
IBC 2003 & 2006
Refer to Section 1607.7.1
Worst case of A or B:
A: 50 lb/ft applied in any direction at the top of wall
B: 200 lbs applied in any direction at any point at the top of the wall
Procedure
A point load at a MidWall™ support is distributed to an adjacent
MidWall™ support based on top track stiffness. Refer to the diagram
at right for an example of the distribution of the point load, P, to adjacent MidWall™
supports.
|
|
|
MidWall™
Spacing1
|
Min. Top Track
|
Max. Tension in Anchor2 (lbs.)
|
Anchorage Options2(4,000 psi minimum concrete strength)
|
|
24" o.c.
(End of Wall requires two MidWall spaced 12")
|
362T150-54
|
2685
|
3/8" HAS Super with HY-150 Max Adhesive, 3-1/2" Embed. (Hilti)
3/8" ASTM A93 GR. B7 Threaded Rod w/ A7 Adhesive, 3-3/8" Embed. (Red Head)
3/8" IXP Anchor w/ Set-XP Epoxy, 3-3/8" Embed. (Simpson)
|
30" o.c.
(End of Wall requires two MidWall spaced 16")
|
362T200-54
|
2890
|
3/8" HAS Super with HY-150 Max Adhesive, 3-3/8" Embed. (Hilti)
3/8" IXP Anchor w/ Set-XP Epoxy, 3-3/8" Embed. (Simpson)
|
32" o.c.
(End of Wall requires two MidWall spaced 16")
|
362T200-54
|
2976
|
3/8" HAS Super with HY-150 Max Adhesive, 3-3/8" Embed. (Hilti)
|
36" o.c.
(End of Wall requires two MidWall spaced 16")
|
362T200-54
|
3166
|
3/8" HAS Super with HVA Capsule Adhesive, 5-1/4" Embed. (Hilti)
|
1 At the end of the wall, MidWall™ is required at adjacent stud spacings.
Spacing given begins after two adjacent end supports.
2 All design data and anchorage options based on 48” maximum wall height.
Back to top ^