MidWall™ Partial Wall Framing and Base Connection

  Product Application  

MidWall is designed to support out-of-plane loading in partial wall systems that are unsupported at the top track. The out-of-plane loads are transferred to the floor system through a ˝” thick plate nested in the flanges of the member with two 3/8” diameter fasteners used for the connection. Available in two lengths, 24” and 48”. MidWall™ may be used in place of standard framing members, or in conjunction with them to frame the wall.

  Material Composition  

MidWall: ASTM A1003/A 1003M, ASTM A653/A653M, Grade 50 (340), 50ksi (340MPa) minimum, 65ksi (450MPa) minimum yield strength, G-90 (Z275) hot-dipped galvanized coating. Material Thickness = 118mil (10 gauge, 0.1017” design thickness)

MidWall Plate: ASTM A36/A36M 08, 36ksi (250MPa) minimum yield strength, 58-80ksi (400-500MPa) tensile strength, ˝” thick.

MidWall Value:
  • Replaces labor/coordination of placing embedded angle into the floor system
  • Provides guide holes for attachment of MidWall to the stud (more efficient attachments compared with tube steel)
  • Reduces the number of anchors used (2 in MidWall vs. 4 in other methods)
  • Creates flexibility as two sizes of MidWall™ are available (24” and 48”) to enable adjustable wall heights
  • current code requirements for handrails and partial walls

Back to top ^

MidWall Nomenclature
MidWall is currently available in two lengths (24” and 48”) and one depth (3.625”). Product nomenclature lists the member depth first followed by the height in inches.
  • For 24” MidWall, designate 362MW-24
  • For 48” MidWall, designate 362MW-48

  MidWall Ordering Information

MidWall is available by the box or in pallet (skid) quantities through your local dealer. Each MidWall™ product will be shipped with a separate base plate.

Designation
Pcs/Box
Lbs/Pc
Pcs/Skid
Lbs/Skid
362MW-24
8
7.5
160
1200
362MW-48 4 13.5 120 1500

 

Back to top ^

  MidWall Installation

  MidWall 24” Assembly Example   MidWall 48” Assembly Example
MidWall 24” is generally used in interior half walls of less than 48” in height. Attach MidWall 24" to stud with #12 screws through all pre-drilled guide holes. Maximum spacing between MidWall connectors is 36” o.c. (see table below). Contact TSN Technical Services at (888) 474-4876 for design recommendations.” MidWall 48" is used in interior half walls equal to 48" in height. Use one MidWall 48" as a substitute for a stud at the specified spacing. Maximum spacing between MidWall connectors is 36" o.c. (see table below). Contact TSN for technical support regarding use in exterior or 6" wide walls.

Back to top ^

  MidWall Design Information
  Criteria

IBC 2003 & 2006
Refer to Section 1607.7.1
Worst case of A or B:
A: 50 lb/ft applied in any direction at the top of wall
B: 200 lbs applied in any direction at any point at the top of the wall

Procedure

A point load at a MidWall support is distributed to an adjacent MidWall support based on top track stiffness. Refer to the diagram at right for an example of the distribution of the point load, P, to adjacent MidWall supports.

MidWall
Spacing1
Min. Top Track
Max. Tension in Anchor2 (lbs.)
Anchorage Options2(4,000 psi minimum concrete strength)
24" o.c.
(End of Wall requires two MidWall spaced 12")
362T150-54
2685
3/8" HAS Super with HY-150 Max Adhesive, 3-1/2" Embed. (Hilti)
3/8" ASTM A93 GR. B7 Threaded Rod w/ A7 Adhesive, 3-3/8" Embed. (Red Head)
3/8" IXP Anchor w/ Set-XP Epoxy, 3-3/8" Embed. (Simpson)
30" o.c.
(End of Wall requires two MidWall spaced 16")
362T200-54 2890 3/8" HAS Super with HY-150 Max Adhesive, 3-3/8" Embed. (Hilti)
3/8" IXP Anchor w/ Set-XP Epoxy, 3-3/8" Embed. (Simpson)
32" o.c.
(End of Wall requires two MidWall spaced 16")
362T200-54 2976 3/8" HAS Super with HY-150 Max Adhesive, 3-3/8" Embed. (Hilti)
36" o.c.
(End of Wall requires two MidWall spaced 16")
362T200-54 3166 3/8" HAS Super with HVA Capsule Adhesive, 5-1/4" Embed. (Hilti)

1 At the end of the wall, MidWall™ is required at adjacent stud spacings. Spacing given begins after two adjacent end supports.
2 All design data and anchorage options based on 48” maximum wall height.

Back to top ^

Back to top ^


          Products are available through local distribution.
Build #: 27