VertiClip® SL w/ 3″ Slots

This slide angle clip is used to connect exterior cold-formed steel curtain wall studs to the primary structure at the head of wall, while allowing for vertical deflection of the structure up to 3″ (2″ up and 1″ down). TSN’s patented Step Bushing Technology provides an anti-friction and anti-seizure connection between the clip and the stud web surface.

Features
  • ICC-ES Approved, report #ESR-2049
  • Load-rated positive mechanical attachment at each stud
  • Patented Step Bushing Technology provides friction-free motion for smooth vertical deflection
  • Eliminates loose friction-held assemblies, heavy deep-leg track, & top row of wall bridging/strapping
  • Load-rated #12 screws provided for vertical deflection connection to stud web
  • Manufactured with certified, 50ksi, 68mil, G90 cold-formed steel

* VertiClip SL is a component in VertiTrack® VTX, TSN’s pre-assembled deflection track.

Order Information
Qty/Box
SL362/400,s3lg,b2d
50
SL600,s3lg,b2d
50
SL800,s3lg,b2d
50
Lbs/Box
SL362/400,s3lg,b2d
20
SL600,s3lg,b2d
33
SL800,s3lg,b2d
43
Qty/Skid
SL362/400,s3lg,b2d
4,500
SL600,s3lg,b2d
2,250
SL800,s3lg,b2d
2,400
Lbs/Skid
SL362/400,s3lg,b2d
1,737
SL600,s3lg,b2d
1,454
SL800,s3lg,b2d
2,064

Nomenclature:
VertiClip SL with 3″ deflection is is designated by type (SL), followed by stud depth in inches multiplied by 100, slot length (s “length in inches” lg), and bushing placement (b “distance from top slot in inches” d).

Example: 6” deep stud, 3″ slot, bushings 2″ down from top of slot
Designate: VertiClip® SL600,s3lg,b2d

Material Composition

ASTM A1003/A1003M Structural Grade 50 (340) Type H, ST50H (ST340H): 50ksi (340MPa) minimum yield strength, 65ksi (450MPa) minimum tensile strength, 68mil minimum thickness (14 gauge, 0.0713” design thickness) with ASTM A653/A653M G90 (Z275) hot dipped galvanized coating.

Catalogs

TSN’s Product Catalogs are an essential resource for the design of cold formed steel. Developed by Engineers, the catalogs contain design data for members, connectors, and fasteners. VertiClip® SL w/ 3″ Slots can be found in the following Catalogs:

TSN Cold-Formed Steel Framing Connections Order Catalog

TSN Connections Technical Catalog

TSN Cold-Formed Steel Framing Connections Technical Catalog

TSN Connections Order Catalog

For a full list of our product catalogs, specification sections, inspection checklists, and research reports please click here.

US Patents #’s 5,467,566 & 5,906,080

VertiClip® SL w/ 3″ Slots Downloads

VertiClip® SL w/ 3″ Slots Applications

The attachment of VertiClip SL to the primary structure may be made with a PAF, screw/bolt anchors or weld and is dependent upon the base material (steel or concrete) and the design configuration.

3" Deflection - Exterior Head of Wall Connection

3" Deflection - Exterior Head of Wall Connection

VertiClip® SL w/ 3″ Slots Installation Instructions

  1. Attach standard leg track to structure. Track will allow for alignment and closure.
  2. Fasten SL to top track at designed stud spacing with engineered fastener.
  3. Attach SL to wall stud with provided screws through Step Bushings.

VertiClip® SL w/ 3″ Deflection – Recommended Allowable Loads (lbs):

33mil (20ga), 33ksi Stud
33mil (20ga), 50ksi Stud
43mil (18ga), 33ksi Stud
43mil (18ga), 50ksi Stud
54mil (16ga), 33ksi Stud
54mil (16ga), 50ksi Stud
68mil (14ga), 50ksi Stud
97mil (12ga), 50ksi Stud
Maximum Allowable Clip Load
VertiClip® SL w/ 3" Deflection - Recommended Allowable Load (lbs): F1 & F2
F1 Load Direction
SL600,s3lg,b2d
w/2 #12 Screws
191
275
248
277
277
277
277
277
277
VertiClip® SL w/ 3" Deflection - Recommended Allowable Load (lbs): F1 & F2
F1 Load Direction
SL600,s3lg,b2d
w/3 #12 Screws
277
277
277
277
277
277
277
277
277
VertiClip® SL w/ 3" Deflection - Recommended Allowable Load (lbs): F1 & F2
F2 Load Direction
SL362,s3lg,b2d
w/2 #12 Screws
377
544
561
617
617
617
617
617
617
VertiClip® SL w/ 3" Deflection - Recommended Allowable Load (lbs): F1 & F2
F2 Load Direction
SL600,s3lg,b2d
w/2 #12 Screws
377
544
561
810
789
1,139
1,571
1,571
1,571
VertiClip® SL w/ 3" Deflection - Recommended Allowable Load (lbs): F1 & F2
F2 Load Direction
SL600,s3lg,b2d
w/3 #12 Screws
565
817
841
1,215
1,183
1,571
1,571
1,571
1,571
VertiClip® SL w/ 3" Deflection - Recommended Allowable Load (lbs): F1 & F2
F2 Load Direction
SL800,s3lg,b2d
w/2 #12 Screws
377
544
561
810
789
1,139
1,610
1,698
1,915
VertiClip® SL w/ 3" Deflection - Recommended Allowable Load (lbs): F1 & F2
F2 Load Direction
SL800,s3lg,b2d
w/3 #12 Screws
565
817
841
1,215
1,183
1,709
1,915
1,915
1,915

Notes:

  • VertiClip SL s3lg, b2d is designed to support horizontal loads, and should not be used in axial load-bearing walls.
  • Allowable loads have not been increased for wind, seismic, or other factors.
  • Meets IBC criteria for light steel framing.  Factor of Safety calculated according to ICC-ES AC261 and Chapter K of AISI S100.
  • Tests performed with with bushings centered in the 3″ slots.
  • The standard bushing placement is 2″ from the top of the slot an allows the structure to settle ½” prior to typical service.
  • Total vertical deflection of up to 3″ (2″ up and 1″ down).
  • #12 screws are provided with each step bushing for attachment to the stud web.
  • Fasten within ¾” of the angle heel (centerline of the 1 ½” leg) to minimize eccentric load transfer.
  • For LRFD strengths contact TSN technical services.
VertiClip® SL w/ 3" Deflection - Load Direction

VertiClip® SL w/ 3" Deflection - Load Direction

Follow us on Social Media