VertiClip® SLD

This slide angle clip for drywall is used to connect metal studs at the head condition (top of wall) to the deck or primary structure while allowing for a total vertical deflection of up to 1½” (¾” up and ¾” down). TSN’s patented Step Bushing Technology® provides an anti-friction and anti-seizure connection between the clip and the stud web surface.

Features
  • ICC-ES Approved, report #ESR-2049
  • NY MEA Approved, report #326-06-M
  • UL classified for all approved dynamic assemblies and finish combinations with 1½” deflection and 1-2 hour fire-ratings
  • Load-rated positive mechanical attachment at each stud
  • Patented Step Bushing Technology® provides friction-free motion for smooth vertical deflection
  • Eliminates loose friction-held assemblies, heavy deep-leg track, & top row of wall bridging/strapping
  • Load-rated #8 screws provided for vertical deflection connection to stud web
  • Manufactured with certified, 50ksi, 33mil, G90 cold-formed steel

* VertiClip SLD is a component in VertiTrack® VTD, TSN’s pre-assembled deflection track.

Order Information

Qty/Box

SLD150

250

SLD250

250

SLD362/400

200

SLD600

100

SLD800

100

Lbs/Box

SLD150

19

SLD250

28

SLD362/400

35

SLD600

28

SLD800

37

Qty/Skid

SLD150

11,250

SLD250

11,250

SLD362/400

9,000

SLD600

4,500

SLD800

4,500

Lbs/Skid

SLD150

855

SLD250

1,260

SLD362/400

1,575

SLD600

1,260

SLD800

1,665

Nomenclature:
VertiClip SLD is designated by type (SLD), followed by stud depth in inches multiplied by
100.

Example: 6″ stud
Designate: VertiClip® SLD

Material Composition

ASTM A1003/A1003M Structural Grade 50 (340) Type H, ST50H (ST340H): 50ksi (340MPa) minimum yield strength, 65ksi (450MPa) minimum tensile strength, 33mil minimum thickness (20 gauge, 0.0346” design thickness) with ASTM A653/A653M G60 (Z180) hot dipped galvanized coating.

Catalogs

TSN’s Product Catalogs are an essential resource for the design of cold formed steel. Developed by Engineers, the catalogs contain design data for members, connectors, and fasteners. VertiClip® SLD can be found in the following Catalogs:

TSN Cold-Formed Steel Framing Connections Order Catalog

TSN Connections Technical Catalog

TSN Cold-Formed Steel Framing Connections Technical Catalog

TSN Connections Order Catalog

For a full list of our product catalogs, specification sections, inspection checklists, and research reports please click here.

US Patents #5,467,566 & #5,906,080

VertiClip® SLD Downloads

VertiClip® SLD Applications

VertiClip SLD comes in a 1½” and 3″ deflection option. The attachment of VertiClip SLD to the primary structure may be made with a PAF, screw/bolt anchors or weld and is dependent upon the base material (steel or concrete) and the design configuration.

SLD_Deflection_InteriorOrExterior_HeadOfWall

1½” Deflection - Interior or Exterior Head of Wall

Installation Instructions

  1. Attach standard leg runner track to deck.
  2. Attach VertiClip SLD to deck (through track).
  3. Attach VertiClip through Step Bushings to wall studs with self-drilling screws provided.

Allowable Loads

18mil (25ga), 33ksi Stud
27mil (22ga), 33ksi Stud
30mil (20ga-Drywall), 33ksi Stud
33mil (20ga-Structural), 33ksi Stud
33mil (20ga), 50ksi Stud
43mil (18ga), 33ksi Stud
43mil (18ga), 50ksi Stud
54mil (16ga), 33ksi Stud
54mil (16ga), 50ksi Stud
Maximum Allowable Clip Load
VertiClip® SLD - Recommended Allowable Load (lbs): F2 Load Direction
SLD150

w/1 #8 screw
51
51
51
51
51
51
51
51
51
51
VertiClip® SLD - Recommended Allowable Load (lbs): F2 Load Direction
SLD250

w/2 #8 screws
132
159
159
159
159
159
159
159
159
159
VertiClip® SLD - Recommended Allowable Load (lbs): F2 Load Direction
SLD362/400

w/2 #8 screws
132
242
322
328
359
359
359
359
359
359
VertiClip® SLD - Recommended Allowable Load (lbs): F2 Load Direction
SLD600

w/2 #8 screws
132
242
322
328
405
405
405
405
405
405
VertiClip® SLD - Recommended Allowable Load (lbs): F2 Load Direction
SLD800

w/2 #8 screws
132
242
322
328
474
488
664
664
664
682

Notes:

  • VertiClip SLD is designed to support horizontal loads, and should not be used in axial load-bearing walls.
  • Allowable loads have not been increased for wind, seismic, or other factors.
  • Strengthening ribs are present in 3-5/8″ and 6″ sizes.
  • #8 screws are provided with each step bushing for attachment to the stud web.
  • Guide holes for attachment to structure are 0.141″ diameter for SLD362/400 and SLD600. Guideholes are not standard for other clip sizes.
  • Fasten within 3/4″ of the angle heel (centerline of the 1-1/2″ leg) to minimize eccentric load transfer.
  • Total vertical deflection of up to 1-1/2″ (3/4″ up and 3/4″ down). Deflection requirements greater than 3/4″ (up and down) are available.
  • For LRFD strengths contact TSN technical services.