BackIt®

BackIt® provides a solid backing solution to support handrails, wall-mounted shelving, and other equipment. Installation is greatly simplified through a simple screw connection to the stud flange, delivering a flexibility for use in 12”, 16”, and 24” stud spacing. Shelf tabs hold a variety of wood backing sizes and shapes, including 1” x 6”, 2” x 4”, and 2” x 6”, in place during installation. BackIt exceeds code-required allowable load resistance of 250lbs in the vertical and horizontal directions.
Features
  • Guide holes for stud and wood attachments
  • Shelf tabs to rest wood upon during installation
  • No pre-determined stud layout
  • May be used with multiple sizes of wood
  • Resists load in the directions recommended by codes
Order Information
Designation Qty/Box Lbs/Box Qty/Skid Lbs/Skid
BackIt® 50 13 2,250 570
BackIt®-End 50 13 2,250 570

Nomenclature

BackIt is designed to be used with studs having flanges up to 1-5/8″ wide,* & is designated BackIt®

* Custom clips are available by request for use with studs having flanges greater than 1⅝”

 

Material Composition
ASTM A1003/A1003M Structural Grade 50 (340) Type H, ST50H (ST340H): 50ksi (340MPa) minimum yield strength, 65ksi (450MPa) minimum tensile strength, 43mil minimum thickness (18 gauge, 0.0451” design thickness) with ASTM A653/A653M G60 (Z180) hot dipped galvanized coating.
Catalogs
TSN’s Product Catalogs are an essential resource for the design of cold formed steel. Developed by Engineers, the catalogs contain design data for members, connectors, and fasteners. BackIt® can be found in the following Catalogs:

TSN Cold-Formed Steel Framing Connections Order Catalog

TSN Connections Technical Catalog

TSN Cold-Formed Steel Framing Connections Technical Catalog

TSN Connections Order Catalog

For a full list of our product catalogs, specification sections, inspection checklists, and research reports please click here.

US Patents #7,559,519

BackIt® Applications

The unique design of MasterClip allows it to be installed either as a vertical deflection connection or a rigid connection.  Attachment to the primary structure may be made with a PAF, screw/bolt anchors, or weld and is dependent upon the base material (steel or concrete) and the design configuration.

BackIt - Wall Backing

Solid Wall Backing for Handrails, Shelving, & Wall Mounted Equipment

Installation Instructions

  1. Place clip flush against wall stud flange and attach to stud with required amount of approved fasteners. Fastener amounts may vary by application.
  2. Rest wood piece on shelf legs and attach to clip with required number of screws through guide holes. For higher loads, attach BackIt to the stud web through a guide hole in the interior leg.

Allowable Loads

The recommended allowable loads and moments reported in this table are for the clip and attachment to the stud only. The attachment to the backing material must be designed by a design professional.

IBC (International Building Code) and OSHA (Occupational Safety and Health Administration) load requirements include the ability of wall backing to resist a minimum of 200lbs of concentrated load, or 50lbs per linear foot in any direction. BackIt® satisfies the load requirements in vertical (F3) and horizontal (F2) directions. Extra testing has been done in the rotational (M1) direction. Product test reports are available upon request. Contact TSN Technical Support at (888) 474-4876 for more information.

BackIt - Load Direction

Load Direction

18mil (25ga), 33ksi Stud
27mil (22ga), 33ksi Stud
30mil (20ga-Drywall), 33ksi Stud
33mil (20ga-Structural), 33ksi Stud
33mil (20ga), 50ksi Stud
43mil (18ga), 33ksi Stud
43mil (18ga), 50ksi Stud
54mil (16ga), 33ksi Stud
54mil (16ga), 50ksi Stud
68mil (14ga), 50ksi Stud
97mil (12ga), 50ksi Stud
Maximum Allowable Member Load
BackIt®, Recommended Allowable Load (lbs) (in-lbs or in-lbs/rad): F2 & F3 & M1
F2 Load Direction

2 Screws
-
-
-
-
276
248
358
312
391
391
391
391
BackIt®, Recommended Allowable Load (lbs) (in-lbs or in-lbs/rad): F2 & F3 & M1
F2 Load Direction

3 Screws
156*
234
258
285
391
372
391
391
391
391
391
391
BackIt®, Recommended Allowable Load (lbs) (in-lbs or in-lbs/rad): F2 & F3 & M1
F3 Load Direction

2 Screws
-
278
322
376
544
560
810
822
1,140
1,140
1,140
1,388
BackIt®, Recommended Allowable Load (lbs) (in-lbs or in-lbs/rad): F2 & F3 & M1
F3 Load Direction

3 Screws
225
417
483
564
816
840
1,215
1,233
1,388
1,388
1,388
1,388
BackIt®, Recommended Allowable Load (lbs) (in-lbs or in-lbs/rad): F2 & F3 & M1
M1 Load Direction
Moment
3 Screws
221
332
366
404
587
527
761
663
956
967
967
967
BackIt®, Recommended Allowable Load (lbs) (in-lbs or in-lbs/rad): F2 & F3 & M1
M1 Load Direction
Stiffness
Up to 0.02 rad
16,800
16,800
16,800
16,800
16,800
16,800
16,800
16,800
16,800
16,800
16,800
967

Load Table Notes

  • The recommended allowable loads and moments reported in this table are for the clip and attachment to the stud only. The attachment to the backing material must be designed by a design professional
  • For LRFD strengths contact TSN technical services.
    * Additional screws may be added to increase the allowable load. F2 value with (4) #12 screws is 207 lbs.